TANK Dewatering System (TDS)
- Hydrocarbons and petroleum products certainly contain some water that is drained in the reservoirs of this water by hand and through the path located on the bottom of the reservoir. This method results in the waste of a lot of hydrocarbons. This machine can automatically detect the percentage of water and hydrocarbons passing through the drainage paths of the reservoirs and activate the alarms when required and prevent the loss of hydrocarbons
PCB Boards
- Design many PCB board such as:
- FPGA Clustering Board
- Virtex 7 + FMC
- ADC
- DAC
- PCI-Ex
- LAN
Smart electronic earthing
This device works like an earth well with many more benefits. To remove any voltage, current and induced noise, the removal of static electricity from the body of all devices connected to it is used. In addition to the above, the device is able to provide a variety of protections to the devices covered as well as their users
Advantages of Art device over earth well
No need for service and maintenance.
Cost between 1.3 to 1.5 well of traditional earth wells.
No need for a lot of space.
Very light and removable.
Ability to run in the shortest possible time.
Ability to use in any place.
No need for thick wires to connect earth.
High reliability in terms of performance.
Has a guarantee of 18 months of company replacement with the highest level of obligations.
10 years after-sales service with the lowest repair costs.
Uses of the device
Fixed and mobile telecommunication towers, BTS towers
Data centers and servers
AT ATMs of banks and financial institutions
Companies, laboratories and research centers to connect computers, laboratory devices and measurements
All houses and residential buildings for cooling / heating systems, elevators and kitchens for connecting the body of the stove, washing machine, dishwasher, microwave, refrigerator, freezer, audio and video systems
Small and large workshops for connecting press, milling and CNC machines
Hospitals, medical centers and offices for connecting monitoring devices, operating room devices, patient electric beds, dental units, sterilizers
General and technical specifications
Elimination of induced voltages and noise and static electricity of the body of the protected devices –
Output power failure when connecting the phase wire to the body of the devices under protection or any connection leading to leakage. (Protection of the device and the user) –
It has a protective fuse, suitable for the current flow of the covered devices –
Detection and activation of the protective circuit in the shortest possible time (less than 30 milliseconds) –
Maintaining the voltage difference between earth and zero to the minimum possible –
Protection against surfactants –
It has an input circuit for urban electricity input (connection and operation in the range of 175 to 255 volts and disconnection outside this range) –
Protection during network null disconnection –
It has a suitable voltage and current display –